Guess it is time for a new drive. Aquarite is not powering up at all. If there is no motor sound at all, and the breaker trips, it could be a bad motor, or it could be a bad breaker, they wear out, especially if used often (instead of the timer switch). Pump shutoff during 24 hours of pouring rain. Hi Scott, if the cracked case seal has any possibility of letting water in, maybe you can silicone it to seal it up. Thank You, Thank You, Thank You! Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Power on LED is intermittently on or off. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. No special tools or lube needed. Do you know what would cause this? I shut the pump down the other night and it will not run. Hi, I have a hayword C48L2N134B3 1.5 HP pool pump. I keep reading that it could be a seal. Not normal, but cant see a reason why that would cause the seal to fail. Same with other sensors. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. My pump seems to trip the GFCI breaker each time it is plugged in. Any insight? Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. the motor makes humming sound but nothing happened, then the motor became burning hot. The components of a Hayward pool heater are also similar to gas heaters made by other manufacturers. Running at low rpm seems to be fine. . Hi Carlos, sounds normal. iv also replaced o rings and filter basket gasket. Inside there is an o-ring that may be out of position, or need lubricant. It only blows air but when I take the lid off water comes out and the basket over flows. All the readings (salt level, amps, etc) are in the correct range. Can I replace a specific part or do I have to buy a new one? It sounds more like a filter problem, one that might be fixed by using a good pool filter cleaner, or you may need new filter media. You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. How To: Troubleshoot a Hayward AquaRite - YouTube Any suggestions? I also replaced the seals. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). Any ideas on what may be going on? Vacuum hose air leaks from splits in an old hose. I believe we have the drawing in air issue at filter, I cannot locate to purchase the o ring seal and valve cover for this model. In my area, the pool gets opened mid May and closed mid September, and runs around 8 hours a day. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. I Manually turned the shaft (which was not turning freely), while the motor was humming. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the Dec 14, 2021. This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. If the cell is still producing chlorine, it should be fine. We would like to show you a description here but the site wont allow us. "headline": "Hayward Pool Heater Troubleshooting",
I shut it down again before the problem got worse. Only get big time cavitation and the basket empties about half. I remplace it and now the sistem works!! and loosing its prime . If any of these readings are outside limits, replace motor. You may give Hayward a call, and ask their tech support directly. I ended up buying a new Hayward pump online however dont want this to happen again. Blue Essence Replacement Salt Chlorinators and Salt Cells Your chlorine generator is still producing chlorine at the moment, which is a good thing. Hi Davy. Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 Fitness View More. Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. They have to stick out about 1/8 wider than the plunger disk. Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. Hi it could be small wood chips stuck in the pump impeller. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. (The factory default is 2800 ppm). Shaft seals may blow out if a valve after the pump is turned or briefly closed while the pump is running. I have digital timer with pump wire going into termials that are screwed down. Any idea what could be causing this issue. A pump that simply wont start is a frustrating problem. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. That is usually the capacitor, a black cylinder in the back of the motor. "width": "611",
Suggestions? Pump lid not on tight, gasket not lubed, or not positioned properly (superpump) Seems to take away the point of getting a variable speed pump if we have to run it on high all the time. I tried to snake the pump but didnt find anything. Also inspect other wires in the back, look for any pinched wires, or wires touching each other. Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. Stackable Rose Gold Wedding Bands, Interesting enough, if I place it in super chlorinate mode, it will produce chorine. Can you help me with this problem Robert, Hi Robert, I dont see an error code 11 in the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true start by making sure that the filter is clean, the valves are open, and the pump lid is on tight. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! Replace with the exact same MFD number, printed on the capacitor. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? Hi Davy! There isnt a break-in period for these units. I checked the possible issues that you mentioned hereno drain plugs on the systemdraining pool is done through the filter via a valve that is after the filter (Perflex). 908-355-7995. If thats what is happening, then the cause of the overheating could be incorrect voltage or fluctuating voltage, incorrect wire size (from breaker or timer to motor), faulty wiring between some of the switches in the rear of the motor, or bad shaft bearings, or poor airflow or blocked air vents, or in some cases, very poor water flow. Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Drying off the terminal board may help, by removing the rear cover. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. My pool pump was running fine until I turned it off. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. hayward blue essence troubleshooting - Habikalli.com Dont feel that resistance when bumping. Entire pump system with pump basket and housing. The blower will continue to run. I would think that going to 1 hp superpump, from a 1.5 hp superpump, would not be a problem. The pump was working well since opening the pool in May, but the last few days it was quite weak. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. Or, soak them in a TSP solution (1 lb of TSP in 5 gals warm water), followed by a soaking in an acid solution, 1 gallon acid added to 4 gallons of water. Spray some ant killer around, and replace the capacitor, but first, check all connections, maybe check incoming power (to the motor) if you have a test meter. Hi Ray, NOW you may have a bad capacitor. Hi Stacey, the build-up of pressure usually means that the filter is clogged, as you likely know. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. Replacement of the gasket inside the valve is the fix. Please note: The majority of our literature and brochures are in English only. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? Motor may still be good. The water does not flow when the pump is turned on. Then dunk them in the pool quickly after the acid, to rinse cleanly. Loose wire connections or touching terminal connections cause sparking. What is happening is that the pump pulls so hard that either an air leak around the pump develops, or the vacuum hose or pool to pump hose begins to crimp and collapse. It was working great up until a week ago. I was only able to read and yes feel voltage in the pool when the main pump was running only. Override this by moving the Main Switch to Super Chlorinate. low speed works fine, pump is three years old. Hello. I have a Hayward Super II pump. My client thinks the motor was 1hp, but he really not sure. I have a six year old Hayward sp3400vsp and theyre recommending I replace it with the pen take intelliflo. No air leaks and it only does this as the heater warms the water up during hot days. Thanks Davy for your quick reply. After removing the capicitor and the thermal load, we were able to get a 7/16 wrench on the shaft at around 12 oclock, but the shaft only has two flat sides and we are only able to move the shaft like 1/12th of a revolution clockwise and counter-clockwise (back and forth between 11 and 12 oclock). If so, put the meter on the terminals where to cord connects inside the motor and see if there is power there. If the wiring is Ok and the error persists, replace the sensor. how to watch past broadcasts on twitch. Flush out the housing to clear debris, then refill with water. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. (I just bought the house and am new to pool upkeep.). If your salt cell is plugged into an GFI outlet, make sure that the test button is not popped, or tripped. We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. This just started. Ive checked out your blog and you had very good info for audience. If that is what is happening to you Im sorry, but your motor is probably gasping its last breaths. I also suspect a bad pressure gauge, if flow is nearly non-existant, pressure should be very low. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. Has more of an impeller type sound. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. Not it says drivererror pump stalled. Anyway, have you checked the cleaner line strainer? I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. Was running fine. Yes, kind of does defeat the purpose, but you may not need to heat the pool all the time, so can still run on low-speed for many hours per day. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Just purchased a Hayward SP32002VSP. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' How are you supposed to move the shaft several revolutions with a 7/16 wrench with all the pegs in the way and the shaft only having two flat sides to get the wrench to lock on to it??? For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. Any suggestions? Hi Davy~ 2. Did you figure out your problem? We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. Sean, Hi Sean, no worries. Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. Hi Deb, probably a bad outlet or a bad cord, or a loose connection on one or both of those. Could also be a clog in the pipe. 3. loose pipe coming into pump, drawing air around fitting threads Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. We hope these charts help solve your Hayward pool heater problems. If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. My pump impeller does not budge. High will run fine but next day I have to do the same, start with low and switch to high. So, grab the opening portion with pliers, while the wrench is holding the shaft still, and turn counter clockwise, it should come off, if it breaks, a new impeller is needed, but thats rare, they usually will budge. Then timer 2 comes on at 3:30 at 2250 rpms, but recently (last 3 mornings) when the second timer at the higher rpms comes on it does not prime and just runs without circulation water through the system. 3. You will have a choice of replacing the bearings or having a local electric motor shop do it, or replace the entire motor, or the entire pump. It is still running the same way, surging. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
We just verified all our time settings. When pump start it work fine but after few hours water stop moving. In the last couple weeks it started getting louder at various times throughout the day. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? I replaced the motor a couple of years ago. "height": "219",
If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. Had the filter for 3 years. You can also pressurize the suction lines using a Drain King, connected to a garden hose and inserted at the skimmer, with a plug inside of the pump on the incoming pipe, or setting the multiport valve on closed. We opened the pool this spring and the pressure rises after 15 to 20 minutes. In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Power Pole Distribution Block, Or you can try a filter cleaner first, to remove oils and scale that may be clogging the filter. Or switch to Pentair, but I wouldnt say theyre better your case is unusual, the pump may have been dropped, suffered some hard knock from a tree branch, or perhaps it had a defective bearing to begin with. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. Good morning. But most aboveground pool pumps are 115V, and certainly is if it came with the cord. Ive checked the voltage coming in before the breaker and after the breaker, (at the motherboard location), replaced the breaker just to be safe, but still, overheats. ), hard to tell until the pump can be tested. But your superpump is fine on your AG pool. Shock the pool first and overfilter, before pulling pump. If outlet is melted, youll need a replacement. It could be dead. Possibly a bad breaker, they do wear out after 20 yrs or so. easier. Press and hold the diagnostic button for 3 to 5 seconds. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. Hi Phil, hmmm, could be a breaker that is going bad they tend to wear out after 20 years or so, especially if they are used often, as a switch. The motor spins CCW? I HAVE THE HEATER Hayward Universal H-Series H250 propane heater connected with the plumbing and electrical. Other causes of high pressure could be unrelated to the pump size, such as an obstruction or restriction on the return line, or a partially closed valve, or plugged wall returns, or eyeball fittings in the pool that are too small. Bearings produce a loud squealy sound. Also check other wires in the back of the motor. In some cases, a small bit of debris (stick or sand) can become lodged between the gasket and the rotor (aka diverter or footpad) and can cause leakage. If any of these readings are outside limits, replace motor. from Either a leaky valve in front of the pump, loose fitting threaded into pump, or loose pump lid/o-ring, or sometimes a loose drain plug, with no Teflon tape on it, and a missing plug o-ring these can all allow air to draw into the pump. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
And if you have Hayward heater error codes on display, that makes finding the problem almost easy! Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. In most cases, it means that your motor is on the way out. Automatic restart is 2 minutes after the error is corrected. I have it set to run for 3 hours in low speed and 5 in high. Move switch to center position and adjust dial to a percentage that you think it needs. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. Reset is immediate after error is corrected. If the motor hums, buzzes, or tries to start, but trips the breaker (or not), could be a bound-up shaft, super clogged impeller, bad capacitor, or bad motor. It worked great for the season. It has now been two days since the technician was here and the pump is still pushing de into the pool at lower RPM speed. Hi Hi Davy, I have a Hayward Super II which has been running well for years. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Not sure if I need to purchase a new pump. You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. The Pool is a Roman 23 in ground. I can see the water trickling in to the filter after a while, and the output becomes very limited. When I turn the switch on for the pool, the breaker flips immediately. I reached into the impeller and grabbed it but it seemed still tight. I tried to restart them & only got a low buzzing type noice. If I try to shut it off, nothing happens. You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free.